TMS380C26

NETWORK COMMPROCESSOR

SPWS010A±APRIL 1992±REVISED MARCH 1993

PARAMETER MEASUREMENT INFORMATION

ethernet timing of RCV signals Ð no RXC

NO.

 

PARAMETER

MIN TYP MAX

UNIT

 

 

 

 

 

330

NORXC

Time with no clock pulse on RXC, when CRS is high (see Note 19)

2

s

NOTE 19: If NORXC is exceeded local clock failure circuitry may become activated, resetting the device.

CRS º1º

330

RXC

Figure 25. Ethernet Timing of RCV Signals Ð No RXC

ethernet timing of XMIT signals

NO.

 

PARAMETER

MIN TYP MAX

UNIT

 

 

 

 

 

340

HBWIN

Delay time from TXC high of the last transmitted data bit (TXEN is high) to COLL

47

cycles

sampled high, so not to generate a ºheart-beatº error

 

 

 

 

 

 

 

 

 

341

COLPUL

Minimum pulse duration of COLL high for guaranteed sample

20 ns + 1 cycle

ns

 

 

 

 

 

342

COLSET

Setup of COLL high to TXC high

20

ns

TXC

340

341

COLL

342

TXD

TXEN

Figure 26. Ethernet Timing of XMIT Signals

POST OFFICE BOX 1443 HOUSTON, TEXAS