TMS380C26

NETWORK COMMPROCESSOR

SPWS010A±APRIL 1992±REVISED MARCH 1993

PARAMETER MEASUREMENT INFORMATION

memory bus timing: external bus master write to TMS380C26

NO.

PARAMETER

MIN MAX

UNIT

96

Setup time of valid data/parity before MBCLK2 falling edge, external bus master write

21

ns

97

Hold time of valid data/parity after MBCLK2 low, external bus master write

0

ns

98

Setup time of MDDIR high before MBCLK2 falling edge, external bus master write

21

ns

99

Hold time of MDDIR high after MBCLK2 low, external bus master write

0

ns

 

MBCLK1

 

 

 

Address In

Address In

 

 

MAX0, MAX2

 

 

 

 

97

 

 

96

MAXPH,

 

MAXPL,

Data/Pty

MADH0±MADH7,

 

MADL0±MADL7

 

Address In

Address In

 

98

 

99

MDDIR

94

95

MACS

Figure 16. Memory Bus Timing: External Bus Master Write To TMS380C26

POST OFFICE BOX 1443 HOUSTON, TEXAS

51

77251±1443

 

Page 51
Image 51
Texas Instruments Memory bus timing external bus master write to TMS380C26, MAX0, MAX2 Maxph Maxpl, Data/Pty