Xerox 6050A, 6030 manual Assigns a defined RGB parameter to Index Number, An index number

Models: 6050A 6030 6050

1 332
Download 332 pages 61.49 Kb
Page 321
Image 321

Command name

Command

Command Meaning and function

Limit

 

 

 

 

Set Blue Parameter

ESC * v # cC

Defines the blue color configuration of

Only

 

 

the color palette.

concatenation

 

 

 

command valid

 

 

 

 

Assign Color Index

ESC * v # iI

Assigns a defined RGB parameter to

Index Number

Number

 

an index number.

 

 

 

 

 

Push/Pop Palette

ESC * p # P

Saves and restores palette

Ignored

 

 

information.

 

 

 

 

 

Start Raster

ESC * r # aA

Sets the controller to the raster mode

 

Graphics

 

and sets the start position and left

 

 

 

margin of a graphic image.

 

 

 

 

 

End Raster Graphics

ESC * r C

Indicates the end of raster graphic

 

 

 

image transfer.

 

 

 

 

 

Transfer Raster Data

ESC * b # V[data]

Transfer's the data of a specified byte.

Data skipped

by Plane

 

However, the CAP does not move to

 

 

 

the next raster position.

 

 

 

The plane pointer is updated but the

 

 

 

row pointer is not.

 

 

 

 

 

Transfer Raster Data

ESC * b #

Transfer's the data of a specified byte

 

by Row/Block

W[data]

as a line or as a block by the current

 

 

 

compression method.

 

 

 

 

 

Set Compression

ESC * b # mM

Determines the compression method.

 

Method

 

 

 

 

 

 

 

Source Raster Width

ESC * r # sS

Indicates the image width of

 

 

 

succeeding raster data.

 

 

 

 

 

Source Raster

ESC * r # tT

Indicates the source raster image

 

Height

 

height of succeeding raster data.

 

 

 

 

 

Move CAP

ESC & a # hH

Moves the CAP horizontally by a

 

Horizontal

 

specified decipoint (1/720 inch).

 

(Decipoint)

 

 

 

 

 

 

 

Move CAP

ESC * p # xX

Moves the CAP horizontally by a

 

Horizontal

 

specified value in Versatec resolution

 

 

 

inch units.

 

 

 

 

 

Move CAP Vertical

ESC * p # yY

Moves the CAP vertically by a

 

 

 

specified value in Versatec resolution

 

 

 

inch units.

 

 

 

 

 

Y Offset

ESC * b # yY

Moves the CAP vertically by specified

 

 

 

pixel rows.

 

 

 

 

 

Appendix 3 HP-RTL Command List (6030/6050)