Dimension
| Table |
|
|
LABEL | DESCRIPTION |
|
|
Temperature Unit (C) | The switch has temperature sensors that are capable of detecting and reporting if the |
| temperature rises above the threshold. You may choose the temperature unit |
| (Centigrade or Fahrenheit) in this field. MAC, CPU and PHY refer to the location of |
| the temperature sensors on the switch printed circuit board. |
|
|
Current | This shows the current temperature in degrees centigrade at this sensor. |
|
|
Max | This field displays the maximum temperature measured at this sensor. |
|
|
Min | This field displays the minimum temperature measured at this sensor. |
|
|
Threshold | This field displays the upper temperature limit at this sensor. |
|
|
Status | This field displays Normal for temperatures below the threshold and Error for those |
| above. |
|
|
Fan speed (RPM) | A properly functioning fan is an essential component (along with a sufficiently |
| ventilated, cool operating environment) in order for the device to stay within the |
| temperature threshold. Each fan has a sensor that is capable of detecting and |
| reporting if the fan speed falls below the threshold shown. |
|
|
Current | This field displays this fan's current speed in Revolutions Per Minute (RPM). |
|
|
Max | This field displays this fan's maximum speed measured in Revolutions Per Minute |
| (RPM). |
|
|
Min | This field displays this fan's minimum speed measured in Revolutions Per Minute |
| (RPM). "<41" is displayed for speeds too small to measure (under 2000 RPM). |
|
|
Threshold | This field displays the minimum speed at which a normal fan should work. |
|
|
Status | Normal indicates that this fan is functioning above the minimum speed. Error |
| indicates that this fan is functioning below the minimum speed. |
|
|
Voltage(V) | The power supply for each voltage has a sensor that is capable of detecting and |
| reporting if the voltage falls out of the tolerance range. |
|
|
Current | This is the current voltage reading. |
|
|
Max | This field displays the maximum voltage measured at this point. |
|
|
Min | This field displays the minimum voltage measured at this point. |
|
|
Tolerance | A tolerance of |
| voltage. |
|
|
Status | Normal indicates that the voltage is within an acceptable operating range at this |
| point; otherwise Error is displayed. |
|
|
Poll Interval(s) | The text box displays how often (in seconds) this screen refreshes. You may change |
| the refresh interval by typing a new number in the text box and then clicking Set |
| Interval. |
|
|
Stop | Click Stop to halt statistic polling. |
|
|
| Statistics |