ZyXEL Communications ES-3024 manual Switch Lockout, Resetting the Switch

Models: ES-3024

1 167
Download 167 pages 41.6 Kb
Page 44
Image 44

Dimension ES-3024 Ethernet Switch

Figure 4-2 Change Password Screen

4.3 Switch Lockout

You are locked out from managing the switch if another administrator is currently logged in. You must wait until he/she has logged out before you can log in.

Moreover, you could lock yourself (and all others) out from the switch by:

1.Deleting the management VLAN (default is VLAN 1).

2.Deleting all port-based VLANs with the CPU port as a member. The “CPU port” is the management port of the switch.

3.Filtering all traffic to the CPU port.

4.Disabling all ports.

5.Assigning minimum bandwidth to the CPU port. If you limit bandwidth to the CPU port, you may find that the switch performs sluggishly or not at all.

Be careful not to lock yourself and others out of the switch.

4.4 Resetting the Switch

If you lock yourself (and others) from the switch or forget the ES-3024 password, you will need to reload the factory-default configuration file.

Uploading the factory-default configuration file replaces the current configuration file with the factory-default configuration file. This means that you will lose all previous configurations and the speed of the console port will be reset to the default of 9600bps with 8 data bit, no parity, one stop bit and flow control set to none. The password will also be reset to “1234” and the IP address to 192.168.1.1.

To upload the configuration file, do the following:

Step 1. Connect to the console port using a computer with terminal emulation software. See the Hardware Connections chapter for details.

4-2

Introducing The Web Configurator

Page 44
Image 44
ZyXEL Communications ES-3024 manual Switch Lockout, Resetting the Switch