■If the power supply plug is unsuitable and you must replace it, refer to the following specifica- tions:
■Brown wire to the Live (Line) plug terminal. The terminal may be marked with the letter L or col- ored red.
■Blue wire to the Neutral plug terminal. The ter- minal may be marked with the letter N or col- ored black.
■Yellow/green wire to the Ground (earth) plug terminal which may be marked with the letter
(E) or the earth symbol or colored yellow/green.
■The Switch 2000 TR operates under SELV condi- tions (Safety Extra Low Voltage) according to IEC 950. This standard is complied with only when the unit is connected to equipment following the same standard.
■Use only fuses of the same type and manufacture with the Switch 2000 TR.
CAUTION: Never remove the cover. The Switch 2000 TR contains no
CAUTION: Never remove an Optional
Positioning the Switch 2000 TR
The Switch 2000 TR is suited for data center and workgroup applications. It can be mounted in a stan- dard
Considerations for Placement
Be aware of the following considerations when installing the Switch 2000 TR:
■Can cable lengths and media be supported prop- erly?
■Is cabling located away from sources of electrical noise such as radios, transmitters and other radio frequency equipment?
■Are all objects removed from the top of the unit or stack?
■Is air flow adequate through the side vents?
■Is unit installed in moisture and