2-2 CHAPTER 2: GETTING STARTED
■If the power supply plug is unsuitable and you
must replace it, refer to the following specifica-
tions:
■Brown wire to the Live (Line) plug terminal. The
terminal may be marked with the letter L or col-
ored red.
■Blue wire to the Neutral plug terminal. The ter-
minal may be marked with the letter N or col-
ored black.
■Yellow/green wire to the Ground (earth) plug
terminal which may be marked with the letter
(E) or the earth symbol or colored yellow/green.
■The Switch 2000 TR operates under SELV condi-
tions (Safety Extra Low Voltage) according to IEC
950. This standard is complied with only when the
unit is connected to equipment following the same
standard.
■Use only fuses of the same type and manufacture
with the Switch 2000 TR.
CAUTION: Never remove the cover. The Switch 2000
TR contains no user-serviceable parts.
CAUTION: Never remove an Optional Slide-in
module filler plate without disconnecting the power
source first.
Positioning the Switch 2000 TRThe Switch 2000 TR is suited for data center and
workgroup applications. It can be mounted in a stan-
dard 19-inch rack, on a wall, or free-standing on a
table or similar surface. A mounting kit with two
brackets is provided for wall or rack mounting.
Considerations for Placement
Be aware of the following considerations when
installing the Switch 2000 TR:
■Can cable lengths and media be supported prop-
erly?
■Is cabling located away from sources of electrical
noise such as radios, transmitters and other radio
frequency equipment?
■Are all objects removed from the top of the unit or
stack?
■Is air flow adequate through the side vents?
■Is unit installed in moisture and water-proof envi-
ronment?