Chapter 7: Second Level Commands June 30, 2006
7-16 SG1-UM-8500-03
<protect port>
The port number to be designated as the protect port (valid value = 1 or 2).
[SFBER (value)]
Signal Fail Bit Error Rate Threshold. Valid values = 3 to 12, Default = 3.
[SDBER (value)]
Signal Degrade Bit Error Rate Threshold. Valid values = 5 to 12, Default = 5.
Example(s)
Configuring OC3 interfaces
Usage
interface atm <slot> \ <port> <sub-interface> [type <ppp point-to -
multipoint|<routed point-to-point> ip <ip address> <mask>|<bridge-route point-to-
point>(ip <ip address><mask>|loopback <loopback number>)|mtu <(1500|1544)>]
Parameter(s)
<slot>
The value 2 is required to select the SONET/SDH interface.
<port>
Use value 1 or 2 to select port 1 or 2.
<sub-interface>
A logical interface number from 1 to 2000.
[type <ppp point-to-multipoint>]
The ppp represents PPP termination.
[type <routed point-to-point> ip <ip address><mask>]
The routed parameter implies routing capability only.
[type <bridge-route point-to-point>]
The bridge-route parameter implies bridge and routing capabilities.
<ip address>
IP address for the interface to be configured.
<mask>
Valid mask for the associated IP address.
Host(config)# port sonet redundancy-enable 2 \ 1 \ 2 \ 2 SFBER 3 SDBER 5
Updated item
Host(config)#
Host(config)# interface