CHAPTER 8. USING THE CONSOLE TO TROUBLESHOOT THE SYSTEM

If the system does not have the remote maintenance option, the Alarm Reported or Ack lamp remains dark when the Alarm or Alm lamp lights for an alarm. In this case, you must

notify the System Manager when an alarm condition exists.

.

 

Optional Alarm Lamps

The Alarm or Alm lamp on the console does not distinguish between major and minor alarms. If such information is required, a feature button is administered as a Major Alarm indicator in V3 and Generic 1 systems. The lamp lights steadily when a major alar-m trouble occurs .

If both the Alarm or Alm and the Major Alarm lamps light, the alarm is major. If only the Alarm or Alm lamp lights, then the alarm is minor.

In V3 and Generic 1 systems, other feature buttons are administered as trouble indicators for links between the system and peripheral support equipment or other sites. The Link Failure lamps light for major, minor, and warning alarms. (In systems with the Hospitality Services package, the PMS Link Failure lamp indicates trouble in the link between the system and the customer-supplied Property Management System.)

You can cause an alarm lamp to go dark by pressing the associated feature button. If the trouble is cleared before system maintenance detects it again, the lamp will remain dark.

Buttons administered for the Facility Busy Indication feature provide alarm lamps for links. The lamps on these buttons remain lighted as long as the links are active but go dark if a link fails .

The system does not report link failures to the remote maintenance center. You must notify the System Manager immediately of any indication of link trouble.

In Generic 1 systems, four hardware alarm indicators can be assigned to users associated with system maintenance and users who monitor system performance. The PMS Printer Alarm lamp lights when the PMS printer interface has a problem, and the Auto Wakeup Alm lamp lights when the interface to the PMS Auto Wake printer has a problem. The SMDR 1 Failure-Inand SMDR 2 Failure-Inlamps light when the interface to the primary and secondary SMDR output device, respectively, has a problem.

Features Used in Troubleshooting

The following features, listed earlier in Chapter 4, can be used by the console attendant for simple trouble isolation and analysis. Step-by-step procedures for each feature are provided.

Automatic Circuit Assurance (V2, V3, Generic 1 systems)—used for monitoring possible trunk failures.

Busy Verification of Terminals and Trunks (V2, V3, Generic 1 systems)—used for placing test calls.

8-2

Page 120
Image 120
AT&T 75 manual Features Used in Troubleshooting, Using the Console to Troubleshoot the System