Chapter 5: Maintenance
5.5.3 VeriPHY
This section describes how to run the VeriPHY Cable Diagnostics. Press to run the diagnostics. It takes approximately five seconds to run. If all ports are selected, it can take approximately 15 seconds. When completed, the page refreshes automatically, and you can view the cable diagnostics results in the cable status table. Note that VeriPHY is only accurate for cables of lengths between 30" and 459"
10- and
Web Interface
To configure a VeriPHY Cable Diagnostics Configuration in the Web interface:
1.Specify which port to check.
2.Click “Start.“
Figure 5-11. The VeriPHY Cable Diagnostics screen.
Parameter Description
•Port: The port where you are requesting VeriPHY Cable Diagnostics.
•Cable Status: Port: Port number.
Pair: The status of the cable pair.
Length: The length (in meters) of the cable pair.
LGB1108A | Page 211 | |
|
|