Chapter 3: Configuration

3.2.2 Rate Limiters

This section describes how to configure the switch’s ACL Rate Limiter parameters. The Rate Limiter Levels from 1 to 16 permit the user to set rate limiter value and units with pps or kbps.

Web Interface

To configure ACL Rate Limiter in the Web interface:

1.Click Configuration, ACL, then Rate Limiter

2.To specific the Rate field and the range from 0 to 3276700.

3.To scroll the Unit with pps or kbps

4.Click the Save button to save the setting

5.If you want to cancel a setting, click the Reset button to revert to previously saved values.

Figure 3-9. The ACL Rate Limiter Configuration screen.

Parameter Description

Rate Limiter ID: The rate limiter ID for the settings contained in the same row.

Rate: Permitted values are: 0–3,276,700 in pps or 0, 100, 200, 300, ..., 1,000,000 in kbps.

Unit: Specify the rate unit. Values permitted are: pps (packets per second) and kbps (kilobits per second).

Buttons:

-Save: Click to save changes.

-Reset: Click to undo any changes made locally and revert to previously saved values.