Chapter 3: Configuration

Parameter Description

Ingress Port : Indicates the ingress port of the ACE. Possible values are:

-Any: The ACE will match any ingress port.

-Policy: The ACE will match ingress ports with a specific policy.

-Port: The ACE will match a specific ingress port.

Frame Type: Indicates the frame type of the ACE. Possible values are:

-Any: The ACE will match any frame type.

-Ethernet Type: The ACE will match Ethernet Type frames. Note that an Ethernet Type based ACE will not get matched by IP and ARP frames.

-ARP: The ACE will match ARP/RARP frames.

-IPv4: The ACE will match all IPv4 frames.

Action: Indicates the forwarding action of the ACE.

-Permit: Frames matching the ACE may be forwarded and learned.

-Deny: Frames matching the ACE are dropped.

Rate Limiter: Indicates the rate limiter number of the ACE. The permitted range is 1 to 16. When Disabled is displayed, the rate limiter operation is disabled.

Port Copy: Indicates the port copy operation of the ACE. Frames matching the ACE are copied to the port number. The permitted values are Disabled or a specific port number. When Disabled is displayed, the port copy operation is disabled.

Mirror: Specify the mirror operation of this port. The permitted values are:

-Enabled: Frames received on the port are mirrored.

-Disabled: Frames received on the port are not mirrored. The default value is “Disabled“.

Logging: Indicates the logging operation of the ACE. Possible values are:

-Enabled: Frames matching the ACE are stored in the System Log.

-Disabled: Frames matching the ACE are not logged.

Please note that the System Log memory size and logging rate is limited.

Shutdown: Indicates the port shutdown operation of the ACE. Possible values are: - Enabled: If a frame matches the ACE, the ingress port will be disabled.

- Disabled: Port shutdown is disabled for the ACE.

Counter: The counter indicates the number of times the ACE was hit by a frame.

Modification Buttons: You can modify each ACE in the table using the following buttons: : Inserts a new ACE before the current row.

: Edits the ACE row.

: Moves the ACE up the list.

: Moves the ACE down the list.

: Deletes the ACE.