Bosch Appliances 7000 Route Power through Intermediate Power Supply Box, VG4-PSU1 / VG4-PSU2

Models: 7000

1 167
Download 167 pages 25.08 Kb
Page 28
Image 28

28 en Installing the Pendant Arm Wall, Corner, and Mast (Pole) MountsAutoDome 7000 Series (IP and HD)

7.3

Route Power through Intermediate Power Supply Box

You may route the main power supply through a VG4-PSU1 (120 V transformer) or through a VG4-PSU2 (230 V transformer) Power Supply Box before connecting the power to a VG4-PA0 (24 V, no transformer) Power Supply Box. The main issue with this configuration is that the 5- pin power out connector from the VG4-PSU1 or VG4-PSU2 does not match to the 3-pin power input of the VG4-PA0 power supply. The illustration below depicts:

A VG4-PSU1/VG4-PSU2 Power Supply Box.

The main power supply connected to the P101 connector and to the grounding screw.

The 24 VAC power out wire connected to the P107 heater power connectors.

VG4-PSU1 / VG4-PSU2

J101

(FUSE)

XF101

P101

LINE NC NEUT

1 2 3

P106

 

GND TXD RXD

C+ C-

 

 

6 5 4 3 2 1

J102

 

XF103

P107

HTRDOME

5 4 3 2 1

 

J103

XF102

 

(LED)

 

P105

GND TXD RXD C+ C-

6 5 4 3 2 1

(FUSE))(FUSE)

Figure 7.3: VG4-PSU1/VG4-PSU2

1

120/230 VAC Power In

5

Transformer

 

 

 

 

2

Ground Wire

6

In/Out Conduit (1/2 in. [15 mm] NPS Fitting

 

 

 

 

3

P101 Connector

7

24 VAC Power Out to VG4-PA0

 

 

 

 

4

P107 Connector

 

 

 

 

 

 

To properly wire the incoming high voltage and the outgoing low voltage lines, refer to this table:

2013.07 1.2.2 F.01U.283.679

Operation Manual

Bosch Security Systems

Page 28
Image 28
Bosch Appliances 7000 manual Route Power through Intermediate Power Supply Box, VG4-PSU1 / VG4-PSU2