74 en Connection

AutoDome 7000 Series (IP and HD)

 

 

2.2K

Figure 11.2: N.O.S. - Normally Open Supervised Connections

1

Dry Contact

3

Dome Connector

 

 

 

 

2

Alarm 1 or 2 only (Pin 5 or 6)

4

Ground (Pin 7)

 

 

 

 

3.From the Settings menu, select Advanced Mode > Interfaces > Alarm Inputs, select the Alarm Input # and N.O. See the table below for contact and condition details.

AutoDome Programmed N.O.S.

Contact

Alarm Condition

 

 

Open

Normal

 

 

Closed

Alarm

 

 

Cut or brake

Tamper

 

 

Configuring a Normally Closed Supervised Alarm

1.Install a 2.2 K end-of-line resistor in the alarm circuit.

2.Connect the alarm wires to input 1 or 2 (pin 5 or 6) and to the ground (pin 7) at the camera.

2.2K

Figure 11.3: N.C.S. - Normally Closed Supervised Connections

1

Dry Contact

3

Dome Connector

 

 

 

 

2

Alarm 1 or 2 only (Pin 5 or 6)

4

Ground (Pin 7)

 

 

 

 

3.From the Settings menu, select Advanced Mode > Interfaces > Alarm Inputs, select the Alarm Input # and N.C. See the table below for contact and condition details.

AutoDome Programmed N.C.S.

Contact

Alarm Condition

 

 

Open

Alarm

 

 

Closed

Normal

 

 

Short

Tamper

 

 

2013.07 1.2.2 F.01U.283.679