60 en Installing the In-Ceiling Mount

AutoDome 7000 Series (IP and HD)

 

 

Figure 9.6: Interface Box Connections

After routing all video, control, power, and alarm wires:

1.Attach a 3/4-inch NPS (20-mm) conduit fitting to the hole in which you bring in the wires. Be sure to thread the inside nut to the conduit fitting.

2.Route the video, control, power, and alarm wires through the conduit fitting and into the Interface Box.

3.Cut and trim the wires allowing for sufficient slack to their respective terminals in the box.

Notice!

If installing the camera to a drywall ceiling, allow enough wire to make the connections in the Interface Box below the ceiling. Refer to the Wire the Interface Box section below.

4.Attach the remaining control data in/out wires to their respective terminals in the Interface Box.

5.Connect the Ethernet cable to its mating connector J101 in the Interface Box.

6.Connect the 24 VAC power wires to the P101 connector in the Interface Box.

Connecting Alarm Inputs and Outputs

4To connect alarm inputs and outputs, attach the supplied 6-pin Alarms In and the 4-pin Alarms Out connector plugs with flying lead wires to the appropriate incoming alarm wires. Alarm Out 4 is a relay.

2013.07 1.2.2 F.01U.283.679

Operation Manual

Bosch Security Systems

Page 60
Image 60
Bosch Appliances 7000 manual Interface Box Connections