Bosch Appliances 7000 manual Agnd, Communi, GND Cations, Out

Models: 7000

1 167
Download 167 pages 25.08 Kb
Page 62
Image 62

62 en Installing the In-Ceiling Mount

 

 

 

AutoDome 7000 Series (IP and HD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J101

 

 

 

 

J103

 

 

 

 

P105

SIG

TXD

RXD

C +

C -

GND

(-)

(+)

 

 

P101

J102

24VAC

24VAC

P103

A3 A4 A5 A6 A7 AGND

 

 

 

P102

 

 

 

 

P104

AGND

OUT3

OUT2

OUT1

 

 

 

 

 

 

 

 

AGND

A2

A1

NC

COM

NO

Figure 9.8: In-ceiling Interface Box

1

Fiber Optics

5

Coax Video

 

 

 

[Not applicable for AUTODOME

 

 

 

7000 Series cameras.]

 

 

 

 

2

Ethernet Video

6

Alarm In

 

 

 

 

3

Dome Power

7

Analog In

 

 

 

 

4

Data In/Out

8

Relay

 

 

 

 

The following table summarizes the pin connectors and their function:

No.

Connector

Pin 1

Pin 2

Pin 3

Pin 4

Pin 5

Pin 6

Pin 7

 

 

 

 

 

 

 

 

 

P103

Alarms In

Alarm 3

Alarm 4

Alarm 5

Alarm 6

Alarm 7

AGND

 

 

 

 

 

 

 

 

 

 

P102

Alarms Out

Alarm 1

Alarm 2

Alarm 3

GND

 

 

 

 

 

 

 

 

 

 

 

 

P104

Analog Relay

Relay N.O.

Relay

Relay N.C.

Earth

Alarm 1

Alarm 2

Ground

 

 

 

COM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P101

24 VAC

Line

Earth

Neutral

 

 

 

 

 

 

 

 

 

 

 

 

 

P105

SERIAL

CODE-

CODE+

Earth GND

RXD

TXD

Signal

 

 

COMMUNI-

(Audio IN-,

(Audio IN+)

(Ground)

(Audio OUT+)

(Audio

GND

 

 

CATIONS

Audio in

 

(Audio)

 

OUT-;

(Ground)

 

 

 

signal

 

 

 

Audio out

 

 

 

 

ground)

 

 

 

signal

 

 

 

 

 

 

 

 

ground)

 

 

 

 

 

 

 

 

 

 

 

J101

Ethernet

Connector Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 9.1: Interface Box Wire Terminals

 

 

 

 

 

 

2013.07 1.2.2 F.01U.283.679

Operation Manual

Bosch Security Systems