40 en Installing the Roof Parapet and Pipe MountsAutoDome 7000 Series (IP and HD)

8

Installing the Roof Parapet and Pipe Mounts

8.1

Description

 

This chapter details how to install an AUTODOME camera to a Roof Parapet or to a Pipe

 

mount. Any differences to the installation between these two mounting systems are noted.

 

The VGA-ROOF-MOUNT is a stationary mount intended for rooftop parapet vertical walls. It is

 

made of light weight aluminum with a corrosion-resistant finish and is used for all Bosch

 

AUTODOME cameras up to a rated load of 29 kg (64 lb). This mount can be fitted to the inside

 

or outside of parapet walls and can swivel for ease of positioning and for servicing the camera.

 

Note that customers must purchase separately the VG4-A-9543 Pipe Mount to use on the end

 

of the VGA-ROOF-MOUNT.

 

The end of the Pipe Mount that is meant to terminate into an enclosure is intended to be field-

 

installed and shall be marked or provided with instructions that identify the equipment

 

necessary to maintain the environmental integrity of the enclosure. In order to maintain the

 

integrity of a Type 4X environment, the connected equipment must have a Type 4X

 

environmental rating. In order to maintain the integrity of a Type 4 environment, the

 

connected equipment must have a Type 4, Type 4X, Type 6, or Type 6P environmental rating.

8.2

Route Wires and Attach Connectors

Power wires must be routed to the left (front) side of the Power Supply Box through a separate electrically earth-grounded conduit. All video, control, and alarm wires must be routed through a second electrically earth-grounded conduit to the right side of the box.

Warning!

External interconnecting cables are to be installed in accordance to NEC, ANSI/NFPA70 (for US application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in

!accordance to local country codes for all other countries.

Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated Fuses are required as part of the building installation. A readily accessible 2-pole disconnect device with a contact separation of at least 3 mm (0.12 in.) must be incorporated.

There are two possible methods to route the video, control, and alarm wires:

Method One is to route the video, control, and alarm wires through the conduit fitting on the right (front) side of the Power Supply Box and out to the AUTODOME Interface Board.

2013.07 1.2.2 F.01U.283.679

Operation Manual

Bosch Security Systems

Page 40
Image 40
Bosch Appliances 7000 manual Installing the Roof Parapet and Pipe Mounts, Vga-Roof-Mount