52 en Installing the Roof Parapet and Pipe MountsAutoDome 7000 Series (IP and HD)

3

6-pin Connector

P103

 

 

 

 

Alarms In (3-7)

 

 

 

 

 

 

 

 

 

 

4

4-pin Connector

P102

 

 

 

 

Alarms Out (1-3)

 

 

 

 

 

 

 

 

 

 

5

100 Ω Resistor

P105

 

 

 

 

Note: When using

 

 

 

 

 

the audio input in

 

 

 

 

 

an AUTODOME

 

 

 

 

 

7000 Series

 

 

 

 

 

camera, remove

 

 

 

 

 

this resistor.

 

 

 

 

 

 

 

 

 

 

6

Data In/Out

P105

AWG

1

Biphase (C-)

 

 

 

26-16

 

For AUTODOME 7000 Series: AUDIO IN –

 

 

 

 

 

(Audio in signal ground)

 

 

 

 

 

 

 

 

 

 

2

Biphase (C+)

 

 

 

 

 

For AUTODOME 7000 Series: AUDIO IN +

 

 

 

 

 

 

 

 

 

 

3

Earth Ground

 

 

 

 

 

 

 

 

 

 

4

RxD +

 

 

 

 

 

For AUTODOME 7000 Series: AUDIO

 

 

 

 

 

OUT +

 

 

 

 

 

 

 

 

 

 

5

TxD –

 

 

 

 

 

For AUTODOME 7000 Series: AUDIO

 

 

 

 

 

OUT – (Audio out signal ground)

 

 

 

 

 

 

 

 

 

 

6

Signal Ground

 

 

 

 

 

 

7

Alarms In (EOLR

P104

AWG

7

Ground

 

Supervised, 1-2)

 

26-16

 

 

 

 

6

Alarm 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Alarm 1

 

 

 

 

 

 

 

 

 

 

4

Earth Ground

 

 

 

 

 

 

8

Relay Output

P104

AWG

3

Normally Closed

 

 

 

26-16

 

 

 

 

 

2

Common

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Normally Open

 

 

 

 

 

 

9

Dome Power

P101

AWG

3

Dome 24 VAC

 

 

 

18-14

 

 

 

 

 

2

Earth Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Dome 24 VAC

 

 

 

 

 

 

10

Heater Power

P107

AWG

2

Heater 24 VAC

 

 

 

18-14

 

 

 

 

 

1

Heater 24 VAC

 

 

 

 

 

 

 

 

 

 

11

RJ45 Ethernet

J101

 

 

 

 

 

 

 

 

 

12

To camera

 

 

 

 

 

 

 

 

 

 

2013.07 1.2.2 F.01U.283.679

Operation Manual

Bosch Security Systems

Page 52
Image 52
Bosch Appliances 7000 manual Awg, Out +