54 en Installing the Roof Parapet and Pipe Mounts

AutoDome 7000 Series (IP and HD)

 

 

7

Ground

For in-ceiling mount only: Low Voltage TTL (3.3V) can also be used.

4Connect the plugs to their mating connectors P103 and P102 on the Pipe Interface Board.

1.To connect supervised alarms and relays, attach the appropriate wires to their terminals on the P104 connector on the Pipe Interface Board (see above).

2.Insert the Pipe Interface Board into the down pipe and fasten the three (3) retaining screws to secure the board to the Dome Cap.

Caution!

!Be careful not to strip the threads when tightening the Pipe Interface Board retaining screws.

Figure 8.13: Pipe Interface Board to Dome Cap Assembly

1

2

3

Interface Board

Retaining Screws (3)

Pendant Mounting Screws (2)

8.7

Attach Pendant to Pipe and Tighten

 

1.

Before attaching the Pendant, visually inspect the Pendant dome and the Interface Board

 

 

connectors for any blocked pin holes and bent pins.

 

2.

Tilt the Pendant enough to place its mounting hook on top of the its housing, over the

 

 

recessed hinge pin of the Dome Cap.

2013.07 1.2.2 F.01U.283.679