AutoDome 7000 Series (IP and HD)

Connection en 75

 

 

Configuring Non-supervised Alarms (inputs 3 through 7)

You can configure alarms 3 through 7 as non-supervised Normally Open (N.O.) or Normally Closed (N.C.) alarms.

Configuring a Normally Open Non-supervised Alarm

1.Connect the alarm to the appropriate input (3 through 7) and ground at the camera.

Figure 11.4: N.O. - Normally Open Non-supervised Connections

1

Dry Contact

3

Dome Connector

 

 

 

 

2

Alarm Inputs 3 to 7

4

Ground

 

 

 

 

2.From the Settings menu, select Advanced Mode > Interfaces > Alarm Inputs, select the Alarm Input # and N.O. See the table below for contact and condition details.

AutoDome Programmed N.O.

Circuit

Alarm Indication

 

 

Open

Normal

 

 

Closed

Alarm

 

 

Configuring a Normally Closed Non-supervised Alarm

1.Connect the alarm to the appropriate input (3 through 7) and ground at the camera.

Figure 11.5: N.C. Normally Closed Non-supervised Connections

1

Dry Contact

3

Dome Connector

 

 

 

 

2

Alarm Inputs 3 to 7

4

Ground

 

 

 

 

2.From the Settings menu, select Advanced Mode > Interfaces > Alarm Inputs, select the Alarm Input # and N.C. See the table below for contact and condition details.

AutoDome Programmed N.C.

Circuit

Alarm Indication

 

 

Open

Alarm

 

 

Closed

Normal

 

 

Bosch Security Systems

Operation Manual

2013.07 1.2.2 F.01U.283.679

Page 75
Image 75