AutoDome 7000 Series (IP and HD)

Installing the In-Ceiling Mount en 61

 

 

PIN

1

 

 

 

WHITE

2

 

 

 

BROWN

3

 

 

 

ORANGE

4

 

 

 

GREEN

PIN

 

 

1

 

 

 

WHITE

2

 

 

 

BROWN

3

 

 

 

ORANGE

4

 

 

 

GREEN

5

 

 

 

YELLOW

6

 

 

 

BLUE

 

 

 

Figure 9.7: Alarm and relay connectors

P102

P103

N.O. COM N.C. A1 A2 GND

P104

1

2

3

4

5

6

7

1

4-pin Alarm

2

6-pin Alarm In

3

7-pin Relay Connector (P104)

 

Connector (P102)

 

Connector (P103)

 

 

 

 

 

 

 

 

Pin

Description

Pin

Description

Pin

Description

 

 

 

 

 

 

1

Alarm Out 1

1

Alarm in 3

1

Alarm Out 4 Normally Open

 

 

 

 

 

 

2

Alarm Out 2

2

Alarm in 4

2

Alarm Out 4 COM

 

 

 

 

 

 

3

Alarm Out 3

3

Alarm in 5

3

Alarm Out 4 Normally Closed

 

 

 

 

 

 

4

Alarm Ground

4

Alarm in 6

4

Earth Ground

 

 

 

 

 

 

 

 

5

Alarm in 7

5

Analog Alarm 1

 

 

 

 

 

 

 

 

6

Alarm Ground

6

Analog Alarm 2

 

 

 

 

 

 

 

 

 

 

7

Ground

 

 

 

 

 

For in-ceiling mount only: Low Voltage TTL (3.3V) can also be used.

 

 

 

 

 

 

 

 

4Connect the plugs to their mating connectors P103 and P102 in the Interface Box.

1.To connect supervised alarms and relays, attach the appropriate wires to their terminals on the P104 connector on the Pipe Interface Board. Refer to the Connection, page 70 chapter for more details on wiring alarms.

2.Attach the lid to the Interface box:

Align the slots on the lid with the two posts at the rear of the Interface box. Rotate the lid down.

Squeeze the ground clips, located at the front of the box, against the Interface box with your fingers before closing the lid to ensure that the lid does not catch on the ground clips.

Secure the lid to the Interface box by pushing the lid down until the clip on the lid catches against the box.

9.6

Interface Box Connections

 

The following figure is a detailed illustration of the In-ceiling Interface box.

Bosch Security Systems

Operation Manual

2013.07 1.2.2 F.01U.283.679

Page 61
Image 61