Control Codes

[ENQ] <31>

Inquire Power Up Error Status

ASCII

[ENQ] <31>

Hexadecimal

05H 1FH

Decimal

<5> <31>

Function

The [ENQ] <31> command reports Power up Error status.

Response

[ACK] <31> <41><n>

Where

 

 

<31>

Is the echo of command

<n>

Status

 

 

bit 0 = No Font file found

 

bit 1 = Required files not found

 

bit 2 = File system has faulted

 

bit 3 = No POR.INI File (Default file has been generated)

 

bit 4 = Codepage requested was not found

 

bit 5 = Primary FAT was damaged, the alternate was used.

 

bit 6 = 1 always

 

bit 7 = 0 always

[ENQ] <32>

Inquire statistics

ASCII

[ENQ] <32>

Hexadecimal

05H 20H

Decimal

<5> <32>

Function

The [ENQ] <32> command returns the internal statistics table.

Response

[ACK] <32> <168> …128 bytes.

Where

 

 

<32>

Is the echo of command

<168>

Length + 40

Statistic table

32 entries each being 4 bytes in big-endian order.

unsigned int Black_Dots; unsigned int Not used; unsigned int Not used; unsigned int Cover_Opens; unsigned int Paper Outs; unsigned int Line Feeds; unsigned int Characters Printed; unsigned int Not used; unsigned int Not used; unsigned int Standby Cycles; unsigned int Power Up Resets; unsigned int Watchdog Resets; unsigned int Flash Erases; unsigned int Not used; unsigned int Auto Cutter_Cycles; unsigned int Init Requests;

Page 172

100-88002 Rev B

 

 

Page 184
Image 184
Epson 100-88002 manual ACK 32 168 …128 bytes