Control Codes

Documented Extended Control commands

The Epic 880TM has a number of Extended Control commands designed to make operation and maintenance of the printer easier for the host application. For further details, refer to the TransAct® Extended Control discussion in Chapter 8.

[ESC] ~V

Return Firmware Checksum

ASCII

[ESC] ~ Z

Hexadecimal

1BH 7EH 5AH

Decimal

<27> <126> <90>

IPCL

none

 

EPOS

[ESC] ~ Z

Description The [ESC] ~ Z command is an extended diagnostics command that returns the Firmware checksum. It does not need to be proceeded with an enabling command. The return is 4 bytes formatted as follows:

~Z<CKH><CKL>

[ESC] ~F

Return Firmware Identification

ASCII

[ESC] ~ F

Hexadecimal

1BH 7EH 46H

Decimal

<27> <126> <69>

IPCL

none

 

EPOS

[ESC] ~ F

Description The [ESC] ~ F command is an extended diagnostics command that returns the Firmware Identification string. It does not need to be proceeded with an enabling command. The return is 14 byte null terminated string containing a 2 byte command ID and a 12 byte firmware ID and revision number. The format is as follows:

~FPE8800-1.06<0>

100-88002 Rev B