Control Codes
Page 128 100-88002 Rev B
The terminating <0> may be replaced with an & or redefined. See [ESC] [EM]T<n>
or &%UT<n> on page 128.
Note: The report is also printed as part of the configuration report.
Function Redefine User Store Termination Character
ASCII [ESC] [EM] T <n>
Hexadecimal 1BH 19H 54H <n>
Decimal <27> <25> <84> <n>
IPCL &%UT <n>
EPOS None
Description This command allows the terminator used to signal the end of the name
field in User Store commands to be modified. The value of <n> is used (in addition to
the <0>) for the terminator. The value of n may be from 0 to 255.
The default value for the second terminator is &. If this command redefines the
terminator to something other than &, the & will no longer function.
Example If &%UT% were sent to the printer, the user store command to run macro
“Demo” would be &%URDemo%.