EPSON AcuLaser C1100 Revision B

TROUBLESHOOTING FIP according to the printer message 134

3.3.3 Error Code FIP

3.3.3.1 Engine related error

FIP-1

Panel Message
Install Y TnrCart
Possible parts that caused the error
Troubleshooting

Toner Cartridge Y HOUSING ASSY-DEVE Y

ANTENNA CTRG HARNESS ASSY MAIN

ANTENNA ASSY-CTRG PWBA MCU

Step Check Yes No
1Model check of Toner Cartridge Y
Is a Toner Cartridge Y that complies with the
specifications attached?
Go to Step[2]. Replace with a
Toner Cartridge
Y that complies
with the
specifications.
2Attachment check of Toner Cartridge Y
Is the Toner Cartridge Y attached correctly?
Go to Step[3]. After re-
attachment
Go to Step[3].
3Does the error recur even if the power is
turned ON/OFF several times? Go to Step[4]. End of
procedure
4Attachment check of HOUSING ASSY-
DEVE Y
Is the HOUSING ASSY-DEVE Y attached
correctly?
Go to Step[5]. After re-
attachment
Go to Step[5].
5Does the error recur even if the power is
turned ON/OFF several times? Go to Step[6]. End of
procedure
6
Check after replacement of Toner Cartridge Y
Replace Toner Cartridge Y.
Does the error recur when the power is turned
ON?
Go to Step[7]. End of
procedure
7ANTENNA CTRG operation check
Disconnect and then re-connect P/J415 on
PWBA MCU.
Does the error recur when the power is turned
ON?
Go to Step[8]. Go to Step[9].
8
Continuity check of HARNESS ASSY MAIN
Disconnect the P/J415 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J415-1J106-2
J415-2J106-1
Go to Step[9]. Repair broken
or shorted part.
9Check after replacement of HOUSING
ASSY-DEVE Y
Replace HOUSING ASSY-DEVE Y (p.383)
Does the error recur when the power is turned
ON?
Go to Step[10]. End of
procedure
10 Check after replacement of ANTENNA
ASSY-CTRG or ANTENNA CTRG
Replace ANTENNA ASSY-CTRG or
ANTENNA CTRG. (p.379) or (p.380)
Does the error recur when the power is turned
ON?
Replace PWBA
MCU. (p.404) End of
procedure
Step Check Yes No