EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY ELEC 406
Table 4-8. Symptoms when the connector is loose
Connector
No. Panel Indication Symptom Error Caused by Connector
Disconnection
P/J400 --- Printing is not
possible. ---
P/J401 Service Req E537 Printing is not
possible. Fuser error
P/J403 C Open Printing is not
possible. The Cover Fuser is open.
P/J404 Jam C, E, F
Jam E, F
Paper Jam at 2nd
BTR ---
P/J405 --- Printed light and
faint ---
P/J406 --- Normal printing ---
P/J407 Service Req E510 Printing is not
possible. ROS Motor error
P/J408 E Open Printing is not
possible. Paper Feeder Rear Cover is open.
P/J409 --- Printing is not
possible. Sensor TR0 error
P/J410 --- The printer does
not work ---
P/J411 --- Normal printing ---
P/J412 Service Req E513 Printing is not
possible. NVM error
P/J413 Service Req E533 Printing is not
possible. Temperature sensor error
P/J414 --- Printing is not
possible. ---
P/J415 A Open Printing is not
possible. COVER FRONT ASSY U is open.
P/J416 Install
Photocondctr Printing is not
possible. IBT Assy error
P/J417 --- Printing is not
possible. Fuser error
P/J418 F Open Printing is not
possible. Housing Chute Fuser is open.
P/J421 Service Req E547 Printing is not
possible. Paper Feeder error
P/J422 Service Req E526 Printing is not
possible. Sensor ADC error
Table 4-8. Symptoms when the connector is loose
Connector
No. Panel Indication Symptom Error Caused by Connector
Disconnection