EPSON AcuLaser C1100 Revision B
TROUBLESHOOTING FIP according to the printer message 191
FIP-38
Panel Message
Jam DM
Jam C
Jam D
Jam LC, G
Jam E
Jam D, E
Jam C, E, F
Jam D, F
Possible parts that caused the error
Troubleshooting
SENSOR LOW PASS SENSOR UPPER PASS
SENSOR T/R SENSOR OHP
SENSOR REGI SENSOR FUSER IN
EXIT SENSOR (Sensor in Fuser)
Step Check Yes No
1Check of error/status code
Specify the problem Sensor by the error/status
code:
Jam DM:
SENSOR LOW PASS
Jam C, Jam D:
SENSOR UPPER PASS
EXIT SENSOR (Sensor in Fuser)
Jam LC, G:
SENSOR T/R
Jam E, Jam D, E:
SENSOR OHP
SENSOR REGI
Jam C, E, F, Jam D, F:
SENSOR FUSER IN
Is there paper remaining on the problem
Sensor?
Remove the
remaining paper
and proceed to
Step [2].
Go to Step [3].
2Does the error recur when a test print is
made? Go to Step [3]. End of
procedure
3Operation check (1) of problem Sensor
Does the ACTUATOR move smoothly
without any damage?
Or, is the light emitter of the Sensor clean?
Go to Step [4]. Re-attach or
replace the
actuator, or
clean the light
emitter.
4Operation check (2) of problem Sensor
The voltage of the common line and signal
line to each Sensor on PWBA MCU is 0 VDC
in a sensor detecting state, or is 5 VDC in a
sensor non-sensing state?
Replace PWBA
MCU. (p.404) Replace the
problem Sensor.