EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY DUPLEX 422
4.12.9 SENSOR UPPER PASS
REMOVAL
1. Remove DUPLEX ASSY. (p.412)
2. Remove COVER-R DUP. (p.413)
3. Remove COVER-L DUP. (p.414)
4. Remove LINK-LATCH and LINK-BUTTON. (p.416)
5. Open COVER UP-DUP TRANS, and remove INVERTER ASSY DUP. Note that
COVER LOW-DUP TRANS and COVER UP-DUP TRANS need not be
removed. (p.417)
6. Remove COVER-INV. (p.415)
7. Remove the screw (silver, with flange, tapping, 10 mm) fastening BRACKET-
SNS to INVERTER ASSY DUP.
8. Remove BRACKET-SNS from INVERTER ASSY DUP together with SENSOR
UPPER PASS.
9. Disconnect connector (P/J124) from SENSOR UPPER PASS.
10. Unhook the 3 hooks fastening SENSOR UPPER PASS to BRACKET-SNS, and
remove SENSOR UPPER PASS.
Figure 4-124. Removal of SENSOR UPPER PASS
Leg_Sec03_124FA
10)-1
7)
8)
9)
10)-2