EPSON AcuLaser C1100 Revision B

TROUBLESHOOTING FIP according to the printer message 225

FIP-67

Panel Message
C Open
Possible parts that caused the error
Troubleshooting

COVER FUSER SWITCH-FUSER DOOR

PWBA MCU LV/HVPS
Step Check Yes No
1Check of open/close state of COVER
Is COVER FUSER closed?
Go to Step [3]. Close the cover.
Go to Step [2].
2Does the error recur when the power is
turned ON? Go to Step [3]. End of
procedure
3Shape check of COVER FUSER
Is the actuator of COVER FUSER that presses
SWITCH-FUSER DOOR deformed or
damaged?
Replace
COVER
FUSER. (p.285)
Go to Step [4].
4
Operation check of SWITCH-FUSER DOOR
Disconnect SWITCH-FUSER DOOR P/J114.
Is there continuity on P114-1P114-2 when
SWITCH-FUSER DOOR is pressed, and does
the continuity stop when the switch is
released?
Go to Step [5]. Replace
SWITCH-
FUSER DOOR.
(p.298)
Actuator
5
Continuity check of HARNESS ASSY MAIN
Do all of the wiring below have normal
continuity?
J403-11J114-2
J403-12J114-1
Go to Step [6]. Repair broken
or shorted part.
6Power supply check to PWBA MCU
Is the specified DC voltage being supplied to
the following terminals on PWBA MCU?
P410-1P410-2: 3. 3 VDC
P410-3P410-4: 5 VDC
P410-5/6P410-7/8: 24 VDC
Replace PWBA
MCU. (p.404) Go to Step [7].
7
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-1J502-1
J410-2J502-2
J410-3J502-3
J410-4J502-4
J410-5J502-5
J410-6J502-6
J410-7J502-7
J410-8J502-8
Replace LV/
HVPS. (p.407) Repair broken
or shorted part.
Step Check Yes No