EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY ELEC 404
4.11.5 PWBA MCU
When using the old PWBA MCU
REMOVAL
1. Remove COVER ASSY LH. (p.295)
2. Disconnect all connectors from the PWBA MCU.
3. Remove the 4 screws (silver, with flange, 6mm) fastening PWBA MCU to the
main unit.
4. Remove PWBA MCU from the main unit.
REINSTALLATION
1. Attach PWBA MCU to the main unit.
2. Fasten PWBA MCU to the main unit with the 4 screws (silver, with flange, 6 mm).
3. Connect all connectors to the PWBA MCU.
4. Attach COVER ASSY LH. (p.295)
Figure 4-110. Removal of PWBA MCU
Leg_Sec03_110EB
403 404 417 418 422
414
416
412
415
421
420
401400
413
410407406
409 408
405
411
3)

3) 3)

3)
4)
2)