EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY DUPLEX 431
4.12.15 ACTUATOR DUP
REMOVAL
1. Remove DUPLEX ASSY. (p.412)
2. Remove the screw (silver, with flange, tapping, 10mm) fastening COVER REAR
from DUPLEX ASSY.
3. Slide COVER REAR to the right, unhook the 2 hooks on the rear of COVER
REAR from DUPLEX ASSY, and remove COVER REAR.
4. Unhook the hook fastening ACTUATOR DUP to DUPL EX ASSY, and remove
ACTUATOR DUP together with SPRING ACTUATOR.
5. Remove SPRING ACTUATOR from ACTUATOR DUP.
REINSTALLATION
1. Attach SPRING ACTUATOR to ACTUATOR DUP.
2. After inserting the right-side shaft of ACTUATOR DUP into the hole on
DUPLEX ASSY, attach ACTUATOR DUP together with SPRING ACTUATOR,
and fasten by the hook.
3. Match the 2 hooks on the rear of COVER REAR with DUPLEX ASSY, and attach
COVER REAR.
4. Fasten COVER REAR to DUPLEX ASSY with the screw (silver, with flange,
tapping, 10 mm).
5. Attach DUPLEX ASSY. (p.412) Figure 4-131. Removal of ACTUATOR DUP
C A U T IO N SPRING ACTUATOR must be firmly hooked onto ACTUATOR
DUP and DUPLEX ASSY.
Leg_Sec03_134FA
CAUTION
4)-2
2)
4)-1
5)
3)