EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY TRANSFER 354
4.5.8 HOLDER-ADC 2ND
REMOVAL
1. Remove COVER ASSY RH. (p.301)
2. Remove CHUTE ASSY-FSR and COVER ASSY-RR 2ND. (p.341)
3. Remove 2ND BTR ASSY. (p.348)
4. Remove PLATE BIAS-2ND. (p.358)
5. Remove SENSOR 2BTR RETRACT. (p.356)
6. Remove CAM ASSY-2ND. (p.350)
7. Remove SPRING-2ND fastening both ends of FRAME ASSY-2ND to the main
unit. (p.346)
8. Remove FUSER ASSY. (p.388)
9. Disconnect connector (P/J431) from SENSOR ASSY ADC.
10. Remove the 2 screws (silver, with flange, 8 mm) fastening HOLDER-ADC 2ND
to the main unit.
11. Remove HOLDER-ADC 2ND from the main unit together with SENSOR ASSY
ADC.
12. Remove the 2 screws (silver, with washer, tapping, 8 mm) fastening SENSOR
ASSY ADC to HOLDER-ADC 2ND.
13. Remove SENSOR ASSY ADC from HOLDER-ADC 2ND.
Figure 4-67. Removal of HOLDER-ADC 2ND
C A U T IO N Step numbers with [ ] in the figure indicate the step of
reinstallation.
Leg_Sec03_512EB
13)
12)
12)
10)
10)
9)
11)
[3)]