EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY PH ASSY 337
4.4.12 MOTOR-PH
REMOVAL
1. Remove FRAME ASSY-PH. (p.327)
2. Unhook the two hooks fastening COVER-HARNESS to FRAME ASSY-PH, and
remove COVER-HARNESS.
3. Unclamp the clamp on DRIVE ASSY-PH, and remove the harness of MOTOR-
PH from the groove on FRAME ASSY-PH.
4. Remove the 2 screws (silver, with flan ge, 6 mm) fastening MOTOR-PH to
FRAME ASSY-PH.
5. Remove MOTOR-PH from FRAME ASSY-PH.
REINSTALLATION
1. Attach MOTOR-PH to FRAME ASSY-PH with the harness of MOTOR-PH
facing the front.
2. Fasten MOTOR-PH to FRAME ASSY-PH with the 2 screws (silver, with flange,
6 mm).
3. Route the harness of MOTOR-PH in the groove on FRAME ASSY-PH, and fasten
with the clamp on DRIVE ASSY-PH.
4. Match the boss and protrusion of COVER-HARNESS with the hole on FRAME
ASSY-PH, attach and fasten with the 2 hooks.
5. Attach FRAME ASSY-PH. (p.327)
Figure 4-53. Removal of MOTOR-PH
C A U T IO N When performing the following work, pay attention to the
attachment direction of MOTOR-PH.
Leg_Sec03_066FB
5)
4) 4)
2)-1
2)-1
3)
3)
2)-2
Front side