EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY ELEC 408
Table 4-9. Symptoms when the connector is loose
Connector
No. Panel Indication Symptom Error Caused by Connector
Disconnection
P/J501 --- Control panel is
not available. ---
P/J502 --- Printing is not
possible. ---
P/J503 --- Main power is not
supplied. ---
D (504) --- Printed light and
faint ---
A (508) --- Entire surface
printed black ---
C (509) --- Printed light and
faint ---
P/J515 --- Printed light and
faint ---