EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY TRANSFER 358
4.5.11 PLATE BIAS-2ND ASSY
REMOVAL
1. Remove COVER ASSY RH. (p.301)
2. Remove CHUTE ASSY-FSR and COVER ASSY-RR 2ND. (p.341)
3. Remove 2ND BTR ASSY. (p.348)
4. Remove the 2 screws (silver, with flange, tapping, 6 mm) fastening PLATE BIAS-
2ND ASSY to the main unit.
5. Unclamp the clamp fastening WIRE ASSY 2BTR, and slightly release PLATE
BIAS-2ND ASSY from the main unit.
6. Remove the screw (silver, tapping, 6 mm) fastening the terminal of WIRE ASSY
2BTR to PLATE BIAS-2ND ASSY.
7. Remove WIRE ASSY 2BTR from PLATE BIAS-2ND ASSY, and remove
PLATE BIAS-2ND ASSY.
Figure 4-70. Removal of PLATE BIAS-2ND ASSY
C A U T IO N When performing the following work, take care not to remove
PLATE BIAS-2ND ASSY too far as it is connected by WIRE ASSY
2BTR.
Leg_Sec03_150FB
4)
4)
5)-2
6)
7)
5)-1
E ring SHAFT-CENT 2ND