EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY DUPLEX 435
4.12.19 HINGE ASSY R
REMOVAL
1. Remove DUPLEX ASSY. (p.412)
2. Remove COVER-R DUP. (p.413)
3. Remove the E-ring fastening HINGE ASSY R to DUPLEX ASSY.
4. Remove HINGE ASSY R from DUPLEX ASSY together with HINGE-R.
5. Remove the 2 screws (silver, with flange, 6 mm) fastening HINGE-R to HINGE
ASSY R.
6. Remove HINGE-R from HINGE ASSY R.
REINSTALLATION
1. Attach HINGE-R to HINGE ASSY R.
2. Fasten HINGE-R to HINGE ASSY R with the 2 screws (silver, with flange, 6
mm).
3. Match the hole on HINGE ASSY R with the D cut surface on SHAFT HINGE,
insert SHAFT DAMPER between the top and bottom pads of HINGE ASSY R,
and attach HINGE ASSY R together with HINGE-R.
4. Fasten HINGE ASSY R to DUPLEX ASSY with the E-ring.
5. Attach COVER-R DUP. (p.413)
6. Attach DUPLEX ASSY. (p.412)
Figure 4-135. Removal of HINGE ASSY RLeg_Sec03_137FA
4)
3)
5)
5)
6)