EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY COVER 298
4.2.14 SWITCH ASSY FUSER, SWITCH-FUSER DOOR
REMOVAL
1. Remove COVER ASSY LH. (p.295)
2. Unclamp the clamp fastening the harness of SWITCH ASSY FUSER and remove
the harness.
3. Remove the screw (silver, with flange, 8 mm) fastening SWITCH ASSY FUSER
to the main unit.
4. Remove SWITCH ASSY FUSER from the main unit.
5. Disconnect the connector (P/J117, blue) from SWITCH ASSY FUSER.
6. Unhook the two hooks fastening SWITCH-FUSER DOOR to BRACKET INLK
FUSER, and remove SWITCH-FUSER DOOR.
7. Disconnect connector (P/J114) from SWITCH-FUSER DOOR.
REINSTALLATION
1. Connect connector (P/J114) to SWITCH-FUSER DOOR.
2. Match the hooks on SWITCH-FUSER DOOR with the attachment position, and
attach to BRACKET INLK FUSER.
3. Connect the connector (P/J117, blue) to SWITCH ASSY FUSER.
4. Match the hole on SWITCH ASSY FUSER with the boss on the main unit.
5. Fasten SWITCH ASSY FUSER to the main unit with the screw (silver, with
flange, 8 mm).
6. Fasten the harness of SWITCH ASSY FUSER with the clamp.
7. Attach COVER ASSY LH. (p.295)
Figure 4-17. Removal of SWITCH ASSY FUSER and SWITCH-FUSER DOOR
C A U T IO N When performing the following work, leave the intermediate
connector on the harness side.
Leg_Sec03_012EB
4)

3) 2)

6)-1
6)-2
7)
5)