EPSON AcuLaser C1100 Revision B

TROUBLESHOOTING FIP according to the printer message 226

FIP-68

Panel Message
G Open
Possible parts that caused the error
Troubleshooting

CHUTE FDR ASSY 500 SWITCH FEEDER DOOR

HARNESS-ASSY FEED MAIN HARNESS-ASSY FEED 1

HARNESS ASSY MAIN PWBA MCU
LV/HVPS
Step Check Yes No
1Shape check of CHUTE FDR ASSY 500
Is the actuator of CHUTE FDR ASSY 500 that
presses SWITCH FEEDER DOOR damaged?
Replace
CHUTE FDR
ASSY 500.
(p.454)
Go to Step [2].
2
Operation check of SWITCH FEEDER DOOR
Disconnect P/J437 from PWBA TRAY 500.
Is there continuity on J437-8J437-9 when
SWITCH FEEDER DOOR is pressed, and
does the continuity stop when the switch is
released?
Go to Step [4]. Go to Step [3].
3Continuity check of HARNESS-ASSY
FEED MAIN
Disconnect P/J437 from PWBA TRAY 500.
Do all of the wiring below have normal
continuity?
J437-8J121-2
J437-9J121-1
Replace
SWITCH
FEEDER
DOOR. (p.464)
Replace
HARNESS-
ASSY FEED
MAIN.
Actuator
4
Continuity check of HARNESS-ASSY FEED 1
Disconnect P/J435 from PWBA TRAY CONT.
Is the continuity normal between all terminals
of J435P608 (connector on Feeder to be
connected to the printer)?
Go to Step [5]. Replace
HARNESS-
ASSY FEED 1.
(p.462)
5
Continuity check of HARNESS ASSY MAIN
Disconnect P/J421 from PWBA MCU.
Is the continuity normal between all terminals
of J421J608 (connector on the printer to
connect Feeder)?
Go to Step [6]. Repair broken
or shorted part.
6Power supply check to PWBA MCU
Is the specified DC voltage being supplied to
the following terminals on PWBA MCU?
P410-1P410-2: 3. 3 VDC
P410-3P410-4: 5 VDC
P410-5/6P410-7/8: 24 VDC
Replace PWBA
MCU. (p.404) Go to Step [7].
7
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-1J502-1
J410-2J502-2
J410-3J502-3
J410-4J502-4
J410-5J502-5
J410-6J502-6
J410-7J502-7
J410-8J502-8
Replace LV/
HVPS. (p.407) Repair broken
or shorted part.
Step Check Yes No