EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY TRANSFER 359
REINSTALLATION
1. Attach WIRE ASSY 2BTR to PLATE BIAS-2ND ASSY.
2. Fasten the terminal of WIRE ASSY 2BTR to PLATE BIAS-2ND ASSY with the
screw (silver, tapping, 6 mm).
3. Match the boss on PLATE BIAS-2ND ASSY with the hole on the main unit, and
attach PLATE BIAS-2ND ASSY.
4. Fasten PLATE BIAS-2ND ASSY to the main unit with the 2 screws (silver, with
flange, tapping, 6 mm), and fasten WIRE ASSY 2BTR with the clamp.
5. Attach 2ND BTR ASSY. (p.348)
6. Attach CHUTE ASSY-FSR and COVER ASSY-RR 2ND. (p.341)
7. Attach COVER ASSY RH. (p.301)
C A U T IO N When performing the following work, route WIRE ASSY 2BTR
connected to PLATE BIAS-2ND ASSY so that it does not come into
contact with CAM ASSY-2ND.
CHECK
P O I N T
When the E-ring on FRAME ASSY-2ND is contacting the PLATE
BIAS-2ND ASSY and is difficult to attach, turn SHAFT-CENT
2ND to facilitate attachment.