EPSON AcuLaser C1100 Revision B
TROUBLESHOOTING FIP according to the printer message 201
11 Check after replacement of SENSOR HUM
& TEMP
Replace SENSOR HUM & TEMP. (p.400)
Does the error recur when the power is turned
ON?
Go to Step [12] . End of
procedure
12 Check after replacement of ROS ASSY
Replace ROS ASSY. (p.375)
Does the error recur when the power is turned
ON?
Go to Step [13] . End of
procedure
13 Check after replacement of PWBA MCU
Replace PWBA MCU. (p.404)
Does the error recur when the power is turned
ON?
Replace LV/
HVPS. (p.407) End of
procedure
14 Power supply check to PWBA MCU
Are each of the power voltages being supplied
to the following terminals on PWBA MCU
from LV/HVPS?
P410-1P410-2: 3. 3 VDC
P410-3P410-4: 5 VDC
P410-5/6P410-7/8: 24 VDC
Replace PWBA
MCU. (p.404) Go to Step [15].
15
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-1J502-1
J410-2J502-2
J410-3J502-3
J410-4J502-4
J410-5J502-5
J410-6J502-6
J410-7J502-7
J410-8J502-8
Replace LV/
HVPS. (p.407) Repair broken
or shorted part.
Step Check Yes No