EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY XERO 369
REINSTALLATION
1. Match the protrusion and boss on GUIDE CRU ASSY AD with the hole on the
main unit, and attach GUIDE CRU ASSY AD.
2. Fasten GUIDE CRU ASSY AD to the main unit with the 7 screws (silver, with
flange, tapping, 6 mm).
3. Attach PLATE-ASSY GND to the main unit, and tighten together with GUIDE
CRU ASSY AD with the screw (silver, with flange, tapping, 6 mm).
4. Attach SPRING-LATCH onto the main unit and the stud on GUIDE CRU ASSY
AD.
5. Attach WIRE ASSY DTN to GUIDE CRU ASSY AD.
6. Fasten WIRE ASSY DTN to GUIDE CRU ASSY AD with the screw (silver, with
flange, tapping, 6 mm).
7. Attach WIRE ASSY BTR, WIRE ASSY IBT and WIRE ASSY BCR to GUIDE
CRU ASSY AD.
8. Attach PLATE-TR-0 to GUIDE CRU ASSY D and GUIDE CRU ASSY AD.
9. Fasten PLATE-TR-0 to GUIDE CRU ASSY D and GUIDE CRU ASSY AD with
the 2 screws (silver, with flange, tapping, 6 mm).
10. Attach SENSOR TR-0. (p.361)
11. Attach BCR CLN XERO ASSY. (p.373)
12. Attach FRAME ASSY-PH. (p.327)
13. Attach 2ND BTR ASSY. (p.348)
14. Attach COVER ASSY RH. (p.301)
CHECK
P O IN T
When performing the following work, work can be performed more
easily with LEVER-LATCH PR on GUIDE CRU ASSY AD closed.
Table 4-3. Symptoms when the connector is loose
Connector
No. Panel Indication Symptom Error Caused by Connector
Disconnection
D (504) --- Printed light
and faint. ---
A (508) --- Entire surface
printed black. ---
G (506) --- Normal printing ---