EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY ROS 375
4.7 ROS

4.7.1 ROS ASSY

REMOVAL
1. Remove COVER ASSY RH. (p.301)
2. Remove COVER ASSY LH. (p.295)
3. Remove COVER MSI. (p.291)
4. Remove COVER FRONT L and COVER FRONT ASSY U. (p.292)
5. Remove COVER INNER L. (p.302)
6. Remove FRAME ASSY-PH. (p.327)
7. Remove CLEANER ASSY. (p.377)
8. Disconnect connector (P/J601) and connector (P/J602) from ROS ASSY.
9. Remove the screw (silver, with flange, 6 mm) fastening the ground lead on ROS
ASSY to the main unit, and disconnect the ground lead on ROS ASSY from the
main unit.
10. Remove the 5 screws (silver, with flange, 10mm) fastening ROS ASSY to the
main unit.
11. Slightly lift up ROS ASSY, remove the boss on ROS ASSY from the hole on the
main unit, and remove ROS ASSY towards the rear of the main unit.
Figure 4-86. Removal of ROS ASSY
C A U T IO N When performing the following work, press LATCH ROTARY on
LATCH ASSY-ROTARY to release the latch, turn FRAME ASSY-
ROTARY by hand, and move HOUSING ASSY-DEVE to prevent
contact with MAG ROLL.
Leg_Sec03_086FA
FRONT REAR

10) 10) 8)

11)

9)-1
9)-2