EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY DUPLEX 432
4.12.16 SENSOR LOW PASS
REMOVAL
1. Remove DUPLEX ASSY. (p.412)
2. Remove the screw (silver, with flange, tapping, 10mm) fastening COVER REAR
from DUPLEX ASSY.
3. Slide COVER REAR to the right, unhook the 2 hooks on the rear of COVER
REAR from DUPLEX ASSY, and remove COVER REAR.
4. Unhook the 3 hooks fastening SENSOR LOW PASS to DUPLE X ASSY, and
remove SENSOR LOW PASS.
5. Disconnect connector (P/J123) from SENSOR LOW PASS.
REINSTALLATION
1. Connect connector (P/J123) to SENSOR LOW PASS.
2. Match the hook on SENSOR LOW PASS with the attachment position, and attach
to DUPLEX ASSY while lifting up ACTUATOR DUP.
3. Match the 2 hooks on the rear of COVER REAR with DUPLEX ASSY, and attach
COVER REAR.
4. Fasten COVER REAR to DUPLEX ASSY with the screw (silver, with flange,
tapping, 10 mm).
5. Attach DUPLEX ASSY. (p.412) Figure 4-132. Removal of SENSOR LOW PASS
C A U T IO N Step numbers with [ ] in the figure indicate the step of
reinstallation.
Leg_Sec03_131FA
2)
3)
5)
4)-1
4)-2
[2)]