EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY COVER 301
4.2.17 COVER ASSY RH
REMOVAL
1. In the case of the DUPLEX specification, remove DUPLEX ASSY. (p.412)
2. In the case of the standard specification, remove COVER FUSER. (p.285)
3. Remove OP PANEL. (p.294)
4. Open COVER MSI.
5. Remove the 4 screws (silver, with flange, 8mm) fastening COVER ASSY RH to
the main unit.
6. Lift up COVER ASSY RH, and unhook the 4 hooks on the rear of COVER ASS Y
RH from the holes on the main unit, and remove COVER ASSY RH.
REINSTALLATION
1. Fit section A of COVER ASSY PH over the front surface of COVER FRONT L
while inserting the protrusion on the front of COVER ASSY RH into the concave
portion on COVER FRONT L, match the four hooks on the rear of COVER ASSY
RH with the holes on the main unit, and attach COVER ASSY RH.
2. Fasten COVER ASSY RH to the main unit with the 4 screws (silver, with flange,
8mm).
3. Close COVER MSI.
4. Attach OP PANEL. (p.294)
5. In the case of the standard specification, attach COVER FUSER. (p.285)
6. In the case of the DUPLEX specification, attach DUPLEX ASSY. (p.412)
Figure 4-20. Removal of COVER ASSY RH
C A U T IO N When performing the following work, be sure to insert the
protrusion on the front side of COVER ASSY RH into the concave
portion on COVER FRONT L.
Leg_Sec03_185EC
CAUTION
6)-2
6)-1
5)
5)
5)
5)
4)
Protrusion
Section A