EPSON AcuLaser C1100 Revision B

TROUBLESHOOTING FIP according to the printer message 221

FIP-63

Panel Message
Replace Photocondctr
Possible parts that caused the error
Troubleshooting

Photoconductor Unit SENSOR TNER FULL

HARNESS ASSY MAIN PWBA MCU
LV/HVPS
Step Check Yes No
1Attachment check of Photoconductor Unit
Is Photoconductor Unit attached correctly?
Go to Step [4]. Re-attach, and
go to step [2].
2Does the error recur when the power is
turned ON? Go to Step [3]. End of
procedure
3Check after replacement of
Photoconductor Unit
Replace Photoconductor Unit.
Does the error occur when the power is turned
ON?
Go to Step [4]. End of
procedure
4Operation check of SENSOR TNER FULL
(Toner Full Sensor)
Remove Photoconductor Unit.
The voltage of P413-11P413-10 on
PWBA MCU is 0 VDC when the sensor
sensing area is blocked, and is 5 VDC when
the sensing area is not blocked?
Replace PWBA
MCU. (p.404) Go to Step [5].
55 VDC power supply check to SENSOR
TNER FULL
The voltage of P413-12P413-10 on
PWBA MCU is 5 VDC?
Go to Step [6]. Go to Step [8].
6
Continuity check of HARNESS ASSY MAIN
Do all of the wiring below have normal
continuity?
J413-10J617-3
J413-11J617-2
J413-12J617-1
Go to Step [7]. Repair broken
or shorted part.
7Continuity check of HARNESS ASSY TNR
FULL
Disconnect P/J617.
Do all of the wiring below have normal
continuity?
P617-1J126-3
P617-2J126-2
P617-3J126-1
Replace
SENSOR
TNER FULL.
(p.374)
Repair broken
or shorted part.
85 VDC power supply check to PWBA MCU
The voltage of P410-3P410-4 on PWBA
MCU is 5 VDC?
Replace PWBA
MCU. (p.404) Go to Step [9].
9
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-3J502-3
J410-4J502-4
Replace LV/
HVPS. (p.407) Repair broken
or shorted part.
Step Check Yes No