EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY DUPLEX 429
REINSTALLATION
1. Match the protrusions on LATCH DUP R and LATCH DUP L with the notches of
hole on DUPLEX ASSY, attach to SHAFT LATCH, turn LATCH DUP R and
LATCH DUP L, and fasten LATCH DUP R and LATCH DUP L to DUPLEX
ASSY.
2. Fasten LATCH DUP L to DUPLEX ASSY with the screw (silver, with flange,
tapping, 10 mm).
3. Attach SPRING LATCH to LATCH DUP R.
4. Match the hole on BKT MOTOR DUP TRANS with the shaft on DUPLEX
ASSY, and attach together with PWBA DUP-L and MOTOR ASSY DUP.
5. Fasten BKT MOTOR DUP TRANS to DUPLEX ASSY with the 4 screws (silver,
with flange, tapping, 10mm).
6. Connect connector (P/J444) to PWBA DUP-L.
7. Route the harness, and fasten the harness by the clamp on BKT MOTOR DUP
TRANS.
8. Attach LINK-LATCH and LINK-BUTTON. (p.416)
9. Attach COVER-L DUP. (p.414)
10. Attach COVER-R DUP. (p.413)
11. Attach DUPLEX ASSY. (p.412)
Figure 4-129. Removal of LATCH DUP R and LATCH DUP L (2)
Leg_Sec03_129FA
9)
11)-1
11)-1
11)-2
11)-2
10)