EPSON AcuLaser C1100 Revision B
TROUBLESHOOTING FIP according to the printer message 160
11
Continuity check of HARNESS ASSY MAIN
Disconnect P/J421 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J421-7J608-4
J421-8J608-3
J421-9J608-2
Replace PWBA
MCU. (p.404) Repair broken
or shorted part.
12 Operation check of ACTUATOR T/R
Does ACTUATOR T/R move smoothly
without any damage? Does it leave the sensing
area of Tray Path Sensor when there is paper?
Does it enter the sensing area wh en th er e is n o
paper?
Go to Step [13] .
Replace
ACTUATOR
T/R.
(p.481)
13 Operation check of SENSOR T/R
The voltage of P437-15P437-14 on
PWBA TRAY CONT is 0 VDC when
ACTUATOR T/R enters the sensing area of
SENSOR T/R, and is 5 VDC when it leaves
the sensing area?
Go to Step [22] . Go to Step [14].
14
5 VDC power supply check to SENSOR T/R
Remove COVER LEFT 500.
The voltage of P437-13P437-14 on
PWBA TRAY 500 is 5 VDC?
Go to Step [15] . Go to Step [17].
15 Continuity check of HARNESS-ASSY
FEED MAIN
Disconnect P/J437 and P/J618 from PWBA
TRAY CONT.
Do all of the wiring below have normal
continuity?
J437-13J618-3
J437-14J618-2
J437-15J618-1
Go to Step [16] . Replace
HARNESS-
ASSY FEED
MAIN.
Step Check Yes No
16
Continuity check of HARNESS ASSY FEED 3
Disconnect P/J618.
Do all of the wiring below have normal
continuity?
P618-4J120-3
P618-5J120-2
P618-6J120-1
Replace
SENSOR
T/R. (p.482)
Repair broken
or shorted part.
17 5 VDC power supply check to PWBA
TRAY 500
The voltage of P435-6P435-5 on PWBA
TRAY 500 is 5 VDC?
Go to Step [9]. Go to Step [18].
18
Continuity check of HARNESS-ASSY FEED 1
Disconnect P/J435 from PWBA TRAY
CONT.
Do all of the wiring below have normal
continuity?
J435-6P608-5
J435-5P608-6
Go to Step[19]. Replace
HARNESS-
ASSY FEED 1.
(p.462)
19
Continuity check of HARNESS ASSY MAIN
Disconnect P/J421 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J421-5J608-6
J421-6J608-5
Go to Step [20]. Repair broken
or shorted part.
20 5 VDC power supply check to PWBA MCU
The voltage of P410-3P410-4 on PWBA
MCU is 5 VDC?
Replace PWBA
MCU. (p.404) Go to Step [21].
21
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-3J502-3
J410-4J502-4
Replace LV/
HVPS. (p.407) Repair broken
or shorted part.
Step Check Yes No