EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY TRANSFER 345
REINSTALLATION
1. Match the boss on SENSOR FUSER IN with the hole on CHUTE ASSY-FSR, and
attach SENSOR FUSER IN.
2. Fasten SENSOR FUSER IN to CHUTE ASSY-FSR with the screw (silver,
tapping, 6 mm).
3. Connect connector (P/J111) to SENSOR FUSER IN.
4. Insert the three protrusions on CHUTE-FSR into the holes on CHUTE ASSY-
FSR, match the holes on CHUTE-FSR with the boss on CHUTE ASSY-FSR, and
attach CHUTE-FSR.
5. Attach PLATE DIS 2ND to CHUTE ASSY-FSR.
6. Tighten and fasten both CHUTE-FSR and the right side of PLATE DIS 2ND to
CHUTE ASSY-FSR with the screw (silver, with washer, tapping, 8 mm).
7. Match DIODE FUSER with the concave portion on CHUTE ASSY-FSR, and
attach.
8. Fasten the right-side terminal of DIODE FUSER to CHUTE ASSY-FSR with the
screw (silver, with washer, tapping, 8 mm).
9. Fasten both the left-side terminal of DIODE FUSER and the left side of PLATE
DIS 2ND to CHUTE ASSY-FSR with the screw (silver, with washer, tapping, 8
mm).
10. Attach CHUTE ASSY-FSR. (p.341)
Figure 4-60. Removal of SENSOR FUSER IN (2)
C A U T IO N When performing the following work, pay attention to the
attachment direction of DIODE FUSER.
Attach so that the white painted side of DIODE FUSER is on the
side where DIODE FUSER is screwed together with CHUTE-FSR.
C A U T IO N When performing the following work, the terminal on DIODE
FUSER must be attached between the washer and the plate.
Leg_Sec03_145FA
8) 9) 7)