EPSON AcuLaser C1100 Revision B
TROUBLESHOOTING FIP according to the printer message 211
FIP-54
Panel Message
Service Req E533
Possible parts that caused the error
Troubleshooting
FIP-55
Panel Message
Service Req E530
Possible parts that caused the error
Troubleshooting
SENSOR HUM & TEMP HARNESS ASSY MAIN
PWBA MCU
Step Check Yes No
1
Temperature check of printer installation site
Has the ambient temperature where the printer
is installed fallen to -7°C or below or reached
or risen to 55°C or more.
Ask the
customer to
improve the
installation
environment for
the printer.
Go to Step [2].
2Check of SENSOR HUM & TEMP
thermistor resistance value
Disconnect P/J413 from PWBA MCU.
The resistance value of P104-4P104-3 is
10k ± 1k (approx. 20°C)?
Go to Step [3]. Replace
SENSOR HUM
& TEMP.
(p.400)
3
Continuity check of HARNESS ASSY MAIN
Disconnect the P/J413 from PWBA MCU.
Is the continuity normal between all terminals
of J413J104?
Replace PWBA
MCU. (p.404) Repair broken
or shorted part.
HARNESS ASSY MAIN SENSOR HUM & TEMP
PWBA MCU
Step Check Yes No
1
Continuity check of HARNESS ASSY MAIN
Disconnect P/J413 from PWBA MCU.
Is the continuity normal between all terminals
of J413J104?
Go to Step [2]. Repair broken
or shorted part.
2Check after replacement of SENSOR HUM
& TEMP
Replace SENSOR HUM & TEMP. (p.400)
Does the error recur when the power is turned
ON?
Replace PWBA
MCU. (p.404) End of
procedure