EPSON AcuLaser C1100 Revision B

TROUBLESHOOTING FIP according to the printer message 216

FIP-58

Panel Message
Service Req E542
Possible parts that caused the error
Troubleshooting

DRIVE ASSY PRO SENSOR IBT RETRACT

HARNESS ASSY MAIN PWBA MCU
LV/HVPS
Step Check Yes No
1Check of connection of DRIVE ASSY PRO
(IBT Cleaner Retract Motor)
Is connector P/J414 connected firmly to
PWBA MCU?
Go to Step [2]. Re-connect the
connector.
224 VDC power supply check to DRIVE
ASSY PRO (IBT Cleaner Retract Motor)
The voltage of P414-3P414-2 on PWBA
MCU 2 is 4 VDC?
Go to Step [3]. Go to Step [8].
3Check after replacement of DRIVE ASSY
PRO
Replace DRIVE ASSY PRO. (p.394)
Does the error recur when a test print is made?
Go to Step [4]. End of
procedure
45 VDC power supply check to SENSOR
IBT RETRACT
The voltage of P415-3P415-4 on PWBA
MCU is 5 VDC?
Go to Step [5]. Go to Step [8].
5
Continuity check of HARNESS ASSY MAIN
Disconnect P/J415 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J415-3J107-3
J415-4J107-2
J415-5J107-1
Go to Step [6]. Replace
HARNESS
ASSY MAIN.
6Check after replacement of SENSOR IBT
RETRACT
Replace SENSOR IBT RETRACT. (p.357)
Does the error recur when a test print is made?
Go to Step [7]. End of
procedure
7Check after replacement of PWBA MCU
Replace PWBA MCU. (p.404)
Does the error recur when a test print is made?
Go to Step [9]. End of
procedure
8Power supply check to PWBA MCU
Are each of the power voltages being supplied
to the following terminals on PWBA MCU
from LV/HVPS?
P410-1P410-2: 3. 3 VDC
P410-3P410-4: 5 VDC
P410-5/6P410-7/8: 24 VDC
Replace PWBA
MCU. (p.404) Go to Step [9].
9
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-1J502-1
J410-2J502-2
J410-3J502-3
J410-4J502-4
J410-5J502-5
J410-6J502-6
J410-7J502-7
J410-8J502-8
Replace LV/
HVPS. (p.407) Repair broken
or shorted part.
Step Check Yes No