EPSON AcuLaser C1100 Revision B
TROUBLESHOOTING FIP according to the printer message 163
11 Continuity check of HARNESS-ASSY P/H1
Disconnect the P/J408 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J408-10J603-3
J408-11J603-2
J408-12J603-1
Go to Step [12] . Replace
HARNESS-
ASSY P/H1.
12 Continuity check of HARNESS-ASSY P/H2
Disconnect P/J603 and P/J102 from PWBA
MCU.
Do all of the wiring below have normal
continuity.
P603-10J102-3
P603-11J102-2
P603-12J102-1
Replace
SENSOR
REGI. (p.336)
Replace
HARNESS-
ASSY P/H2.
13 5 VDC power supply check to PWBA MCU
The voltage of P410-3P410-4 on PWBA
MCU is 5 VDC?
Replace PWBA
MCU. (p.404) Go to Step [14].
14
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-3J502-3
J410-4J502-4
Replace LV/
HVPS. (p.407) Repair broken
or shorted part.
15
24 VDC power supply check to P/H MOTOR
The voltage of P409-6P409-5 on PWBA
MCU is 24 VDC?
Go to Step [16] . Go to Step [18].
Step Check Yes No
16 Continuity check of HARNESS-ASSY P/H1
Disconnect the P/J409 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J409-1P604-6
J409-2P604-5
J409-3P604-4
J409-4P604-3
J409-5P604-2
J409-6P604-1
Go to Step [17]. Replace
HARNESS-
ASSY P/H1.
17 Check after replacement of MOTOR-PH
Replace MOTOR-PH. (p.337)
Does the error recur when a test print is made?
Replace PWBA
MCU. (p.404) End of
procedure
18
24 VDC power supply check to PWBA MCU
The voltage of P410-5/6P410-7/8 on
PWBA MCU is 24 VDC?
Replace PWBA
MCU. (p.404) Go to Step [19].
19
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-5J502-5
J410-6J502-6
J410-7J502-7
J410-8J502-8
Replace LV/
HVPS. (p.407) Repair broken
or shorted part.
20 Continuity check of HARNESS-ASSY P/H1
Disconnect the P/J408 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J408-1J603-12
J408-2J603-11
Go to Step [21]. Replace
HARNESS-
ASSY P/H1.
Step Check Yes No